Loading...
Plating is the part of a metal frame that fails first and is specified last. Buyers routinely approve a finish from a photograph and then discover, two seasons later, that a third of the shipment has gone dull at the temple tips or that a market has rejected the goods on a nickel test that nobody ordered.
Three independent questions sit inside the word "plating": will it resist corrosion, will it stay on, and will it release nickel. They are tested differently, they fail for different reasons, and one of them is a legal gate rather than a quality preference.
The salt spray test exposes the finished frame to a continuous fine mist of neutral salt solution under controlled conditions, and the number quoted in a specification is the hours completed before visible base-metal corrosion appears. The hours are not a quality score; they are a ranking under one specific accelerated condition.
What the hours actually tell you:
﹞ It is an accelerated corrosion test, not a wear test.A frame that survives 96 hours is not necessarily better in daily use than one that survives 48, though it is a reasonable proxy for coating integrity.
﹞ Edges and holes fail first.Coating is always thinner on a cut edge or around a drilled hole, so the failure site is predictable and should be the place the inspector looks.
﹞ The verdict needs a definition."No corrosion" is meaningless without an area threshold. Most order specifications define failure as corrosion products covering more than a stated percentage of a defined surface, excluding edges.
﹞ White and red products mean different things.On plated steel, white corrosion is the zinc or nickel layer breaking down; red corrosion means the base metal has been reached. A report that does not distinguish them cannot be compared with another report.
|
Duration |
Where it is used |
What it implies about the coating stack |
|
24 hours |
Entry-level fashion programmes, short-season SKUs |
Thin nickel with a decorative chromium flash; adequate if the frame is not expected to survive daily wear for years |
|
48 hours |
Mainstream order specification for most European and North American retail |
Nickel layer in the mid single digits in micrometres, full coverage on edges |
|
72每96 hours |
Premium programmes, humid markets, brands with long warranties |
Thicker barrier layer, controlled bath chemistry, careful racking to avoid contact marks |
Decorative plating on eyewear is almost always a stack rather than a single layer, and each layer has a different job. Understanding the stack explains why quoting a single thickness number is not enough.
|
Layer |
Typical thickness |
Function |
|
Copper strike |
0.5每2 µm |
Adhesion to the base metal and levelling of surface defects |
|
Nickel |
3每10 µm |
The corrosion barrier and the layer that carries most of the durability |
|
Decorative chromium |
0.1每0.3 µm |
Hardness, wear resistance and the final colour; too thin to protect on its own |
|
PVD coating |
0.5每2 µm |
Colour and wear resistance without nickel, but limited corrosion barrier |
|
Gold flash |
0.03每0.1 µm |
Colour only; wears through quickly at contact points |
The practical consequence is that the nickel layer, not the top coat, determines whether the frame survives. A thick decorative chromium layer over a thin nickel layer looks no different on the shelf and fails much sooner. When a supplier quotes "chrome plated", the question to ask is the nickel thickness underneath.
PVD is not automatically better.PVD gives excellent colour and wear resistance and avoids nickel entirely, which is valuable for skin-sensitive markets. But a sub-micron PVD layer over a poorly prepared substrate can corrode at pinholes faster than a well-built nickel-chromium stack. The substrate preparation matters more than the coating name.
Under REACH Annex XVII, entry 27, articles intended to come into direct and prolonged contact with the skin must not release more than 0.5 micrograms of nickel per square centimetre per week. Spectacle frames fall squarely inside that definition: the temples rest on the skin, the front touches the nose and cheeks, and metal nose pads or their arms are in continuous contact.
Two things about this requirement catch buyers out.
﹞ The test is a release test, not a content test.A nickel-containing alloy can comply if the coating is intact and the release is low; a low-nickel alloy can fail if the surface is porous. Compliance comes from EN 1811 release testing, preceded by EN 12472 simulated wear and corrosion, which is designed to represent two years of use.
﹞ "Nickel free" is a claim, not a material description.It needs the same test evidence as a release claim, because trace nickel is present in many alloys and in plating baths. A supplier statement is not a test report.
The parts that matter are the ones people forget: hinge screws, the metal core inside an acetate temple, spring housings and any decorative rivet that sits against the skin. A titanium front with a stainless screw can still fail a market's nickel requirement if the screw is the wrong grade.
|
Symptom |
Root cause |
What to change |
|
Blistering or peeling at edges |
Insufficient cleaning before plating, or coating too thin at the edge |
Pre-treatment sequence and racking position |
|
Corrosion at a single point |
Pinhole in the coating, often over an inclusion in the base metal |
Base metal quality and polishing before plating |
|
Patchy colour or dull areas |
Contact marks from the rack, or current density variation |
Rack design and part orientation |
|
White bloom after shipping |
Residual salts from inadequate rinsing, activated by humidity in transit |
Rinse stages and drying before packing |
|
Colour drift between lots |
Bath chemistry drift, especially in gold and bronze tones |
Bath analysis schedule and colour control on a physical standard |
1. Salt spray hours and the failure definition〞 the duration, the standard, and the corrosion area threshold that counts as failure.
2. Nickel thicknessas a minimum, not a range, plus the decorative layer.
3. Nickel release requirement with the test standards named, and the parts list it covers, including screws and core wires.
4. Adhesion test〞 cross-hatch or bend test, so peeling is caught before shipment rather than after.
5. Colour standard〞 a physical approved sample plus a measured value, because photographs do not control colour.
6. Report per lot〞 salt spray and nickel release reports tied to the production lot, not to a generic material certificate.
A metal frame is sold on its finish and returned on its finish. The specification above costs one page and replaces the most common after-sales conversation in the category.
For mainstream retail in temperate markets, it is the usual baseline and a reasonable one. For humid climates, long warranties or premium positioning, specify 72 to 96 hours and confirm the nickel layer thickness that makes it achievable.
PVD itself contains no nickel, so it helps, but the result depends on the substrate and on every metal part that touches the skin. Test the finished frame, not the coating in isolation.
Stainless steel contains nickel. The claim needs release test evidence, and in some markets the word "free" is restricted regardless of the measured result. Describe the measured release rather than the material.
Because the colour comes from the top layer, and its thickness and chemistry differ. A 0.1 micrometre chromium layer and a 0.3 micrometre one reflect differently, and gold tones shift visibly with a few tenths of a micrometre.
Yes, if they are visible and touch the skin. Hinges and screws are the parts most often left out of the specification and most often responsible for a nickel failure.